Multifunctional Thermal Ciculation Valve
Use of a Multifunctional Thermostatic Circulation Valve (MTCV), available from, All Valve Industries, for thermal balancing of a hot water system reduces the consumption of electricity and can save up to 20% on the running costs of a circulation pump.

Operation of the MTCV:

Multifunctional Thermostatic Circulation Valve (MTCV) operates by utilising a thermal wax element to control the flow of water and consequently the water temperature.

The thermal element reduces the flow of water by closing at increasing temperatures and opening at decreasing temperatures.

The valve is placed on the return line of each riser on the hot water circulation system, limiting the volume of water in the circulation pipes to the minimum required level.

The valve is adjustable between 35°C and 60°C and comes pre-set at 50°C.

By presetting the valve to a value anywhere between this range, the required hot water temperature will be kept to a constant within the system.

Why thermal balancing?

  • A thermal MTCV valve automatically balances a system according to the preset temperature. By balancing the volume of water through each riser, it is possible to distribute the hot water evenly throughout the system, keeping the system set at a comfortable temperature for the end user
  • The MTCV can be installed in new hot water systems or retrofitted into one that needs balancing. The goal of balancing a circulation system is to supply hot water to all users in a short period of time, as well as reducing the tapping time of hot water to save water
  • Legionnaire bacteria survive and multiply at temperatures between 20°C and 45°C. It is therefore critical to maintain pipe temperature for a hot water system to at least 50°C. At this temperature, bacteria such as Legionnaire cannot survive

Upgrades for automatic disinfection:

The MTCV standard version A can easily and quickly be upgraded for thermal disinfection against the Legionella bacteria in hot water systems.

After removing the disinfection plug, the thermostatic disinfection module can be mounted. The regulation module in basic version A works within the temperature range 35 - 60°C.

When the temperature of the hot water increases above 65°C the disinfection module opens a bypass, allowing hot water to circulate through the system for disinfection.

The MTCV can also be upgraded to the electronically regulated disinfection process.

The CCR Master controls the MTCV valves via thermoactuators providing complete control over the disinfection process in each individual riser of the hot water system.

23-May-2007

Contact All Valve Industries

Name:
Company Name:
Contact Number:
Email Address:
Your State:
Your Message:

Please uncheck this box if you don't want to receive the latest product updates in Infolink Weekly Product News, Infolink's weekly eNewsletter.

does not match
 
Your contact details will be passed onto this company ( see our Privacy Policy )
More Articles

All Valve Industries News


Cim Valve B12 lockable cap Cim Valve B12 lockable caps available from All Valve Industries (3-Nov-2008)
Cim Valve B12 lockable cap is available from All Valve Industries. B12 lockable cap offers security from tampering or unauthorised use when the lockable cap is in place. The Cim Valve B12 range allows a ball valve to be locked in the open, closed or any other ‘in-between’ position.

Double regulating valve Balancing valves available from All Valve Industries (29-Oct-2008)
The benefits of using a fixed orifice style double regulating valve.

Murray Pinch Clamps Murray Pinch Clamps - for the irrigation industry (28-Oct-2008)
When it comes to irrigation, look no further than a Murray stainless steel pinch clamp.

Caleffi range of valves Solar valves available from All Valve Industries (26-Mar-2008)
All Valve Industries imports the Caleffi range of valves and associated products.

Instantaneous water heater ball valves Instantaneous water heater ball valves from All Valve Industries (11-Mar-2008)
Designed to allow a quick installation without having to use all those brass fittings, the new instantaneous water heater ball valve comes complete with a loose nut and tail.

News Sign up View all  |  RSS Feed

Related Articles

Solar hot water systems available from Conergy (8-Jan-2009)
Conergy offer a wide range of solar hot water systems. TS series hot water systems are eco-friendly water systems with higher REC values. These hot water systems can be mounted easily and consist of 300 litre or 180 litre tanks. The TS series hot water system, provided by Conergy, is available either with electric boosting or gas boosting. These hot water systems minimise the heating costs and available as closed or open circuit systems.

Solar water pumps available from Conergy (6-Jan-2009)
Conergy provide a diverse range of solar water pumps. The LVM Amazon solar water pump is a centrifugal submersible pump available in 24V as well as 12V models. These solar water pumps are suitable for all types of water including fresh water, salt water and diesel.

Home automation from LetsAutomate (5-Jan-2009)
LetsAutomate specialise in designing home automation systems for residential and commercial market. LetsAutomate carry out complete cabling and electrical work including lighting, audio and video, heating, ventilation, air conditioning, multimedia, security and irrigation.

Independent and integrated solar systems from Zane Solar Systems Australia Independent and integrated solar systems from Zane Solar Systems Australia (15-Dec-2008)
Zane Solar Systems Australia supply a wide range of solar systems. The Zane solar system pays for itself in just a few years.

Direct heating systems available from DEVI Heating Systems Direct heating systems available from DEVI Heating Systems (15-Dec-2008)
Direct heating systems, available from DEVI Heating Systems, are placed near the floor surface making them relatively fast acting. They may be installed either as a total heating system or as a background heating system.

Access over 2000 Construction and Architecture jobs online!